Skip to main content
Tag

Energy Ratings

What Air Conditioner Unit size do i need? Call Jason & the Team at Coastal Today for a quote and professional advice | PH: 0421 726 203

What size Air Conditioner best suits me?

By Air Conditioning News

Helping Gold Coasters choose the correct Air Conditioning Unit suitable to their individual needs!

2.5Kw for a bedroom, 5Kw for a garage sized room and a 7Kw for a big lounge. Sounds simple enough and in some cases that might work however there are other factors to consider when trying to find the correct air conditioner unit size for a room.

The size and shape of the room play the major part, however room insulation and the amount of sunlight also play an important role. The orientation of the room also makes a huge difference.

Size of the Room

Installing an Air Conditioning Unit that is too big for a room seems like a good idea as it will cool the room down quicker, however, there may be side effects. If the unit is too over sized, it will cool the room to fast not allowing the moisture to be removed from the room. The room will feel cool however the room will feel uncomfortable due to the humidity being too high.

Comfortable Air Conditioning in your Gold Coast living room

Comfortable Air Conditioning in your Gold Coast living room

Buying an Air Conditioning Unit that is too big will also cost you more to buy the unit. The installation price may be higher also. The unit may also not have as good an energy star rating costing more to run.

Putting in an air conditioning unit that is to small has the obvious disadvantage of working too hard to achieve the desired temperature. A unit that works to hard will have a lot more wear and tear. Running costs will be higher and you may void the warranty due to it being undersized and being overworked.

A correctly sized air conditioning unit will cool the room in a reasonable enough time to remove the humidity. Once the room is at the correct temperature the compressor will wind down allowing it to maintain the room temperature and allowing for maximum energy savings. This is where the inverter compressor really shines – as its energy saving are best at this reduced load.

TYPE OF ROOM: What is the room being used for? Bedrooms have a smaller heat load as they are typically used only at night. Rooms with a number of heat sources (people or computers) may need to be factored into the calculation.

ORIENTATION OF ROOM: Rooms that face east usually receive the morning sun and west facing rooms receive more sun in the afternoons. North facing rooms receive sun most of the day. South facing rooms usually need less cooling as they do not receive any direct sun.

Air Conditioner Size room orientation

GLASS WINDOWS: Glass windows allow a lot of heat transfer from outside.  Ideally double glazing will be optimal as it will drastically reduce this heat transfer. However this is not usually viable due to the cost. This is where internal and external shading becomes necessary.

SHADING: External shading such as blinds, awnings and shadows can drastically reduce the amount of heat build-up in a room. Internal shading such as curtains and blinds also make a difference. The more direct sun you can keep from entering your house the cheaper it will be to keep it cool or warm.

INSULATION: Rather than relying on a thin layer of plasterboard between the hot roof space air and the inside of your house, having a layer of ceiling insulation will make a huge difference. There can be a 10 degree difference between the interior of a house with and without ceiling insulation. Insulated walls can also make a huge difference. Apartment usually have concrete floors and ceiling and this is also a good insulator.

SEALING: Large open rooms will not hold the heat as well as a bedroom with a closed door. Most open plan living areas open up to hallways and other rooms without doors. Gaps under doors and between rooms can all add up to heat transferring between rooms.

 

 

 

THE AIR CONDITIONING UNIT

INDOOR POSITIONING: Although not so critical in bedrooms as they are usually small square shaped rooms the positioning of the air conditioning unit in the larger rooms can help a lot. The most central location can help even air flow which helps with an even temperature in the room.

OUTDOOR POSITIONING: Most outdoors positions are suitable for residential air conditioning units. That is because they are usually placed against a wall. If you are putting the outdoor unit on a roof facing it blowing north is usually best. This is because you do not want any direct sun blowing on the back of the coil. The coils transfer heat and if the sun is shining on these coils it can add an extra load on the system having to get rid of this heat.

EFFICIENCY:  Almost all air conditioning units are inverter models these days. These have a compressor which regulates its speed as to how much heating or cooling it needs to do. These variable speed compressors have a huge energy savings compared to the older either ‘on or off’ models.

Energy ratings are usually similar throughout the size ranges. With the smaller 2.5Kw units usually having about 5 stars for cooling and heating. By the time you get up to 7kw models the star ratings drop to about 2.5 stars. And usually about 2 for the 8 and 9Kw models.

Weather its a cheaper Kelvinator or more expensive Daikin unit they usually have similar energy ratings.

 

Air Conditioner Size star rating

 

 

 

Calculating the size of your room for your Brand New Air Con Unit

The air conditioner unit size needs to be calculated for the room.

We need to find the area of the room. This is calculated by length x width.

Air Conditioner Size Length x width

Ceilings are usually about 2.4 meters high. Anything higher than this should be added to the calculation. Cathedral ceiling usually have more heat transfer due to having no ceiling space and being closer to the roof tiles or tin above.

After finding the area of the room we need to multiply this by the amount of watts per square meter. The number of watts depends on the room.

A bedroom can be calculated at about 0.13 Kw to cool 1 x square meter – this has a lower value as most bedrooms are only used at night times when there is not a large heat load on the building.

Living areas can be calculated at about 0.15 Kw to cool 1 x square meter.

The Kw per square meter may be more depending on room insulation, sunlight and room orientation. The height of the ceiling can also affect the calculation.

Step by step method:

1: Measure the width of the room in meters the air conditioner will be in.

2: Measure the length of the room in meters the air conditioner will be in.

3: Multiply the length and the width of the room to find the area of the room.

4: Multiply the area of the room by the Kw per square meter 0.13 – 0.15Kw

Example:  You have garage that you want to air condition.

1: Measure the width of the room -The garage is 6 metres wide.

2: Measure the length of the room -The garage is 6 metres long.

3: Multiply the length and the width of the room.

The garage is 6 metres long and 6 metres wide.

6 x 6 = 36

The area that you need to cool would be 36 metres squared.

4: Multiply the area of the room by the Kw per square meter.

If you multiply 36 by 0.15 you will get 5.4.

You would need an air conditioner size unit with a cooling capacity of about 5.4kW.

You may be able to use a 5Kw unit if the room is fairly insulated and has no direct sun.

If you have a large panel garage door that receives the direct sun you would be better off choosing a air conditioner size unit of about 6Kw.

TYPICAL UNIT SIZES

Room size Capacity
Small Up to 20m2            Bedroom, study, small kitchen 2–2.5kW
Medium 20–40 m       Bedroom with ensuite, small lounge 2.5–5kW
Large 40–60 s m2       Large bedroom, mid-sized lounge, large kitchen 5–8kW
Extra Large 60–80 m2 Open-plan areas, large lounges 7–9kW

 

air conditioning energy star rating

Air Conditioning Energy Star Rating

By News

What Is The Air Conditioning Energy Star Rating?

The air conditioning energy star rating is an indicator of how efficient an appliance is compared to a similar product of the same size.

This air conditioning energy star rating is based on standardised testing which is required by law and conducted in line with Australian and New Zealand standards. It is a simple and fair way of comparing the energy consumption of products that perform a similar task.

The higher the amount of stars the more energy efficient this unit will be.

Most split system air conditioning units will have an energy star rating of between 1 and 6. These stars can increase in half star increments.

Ducted air conditioning units are not required to have an energy rating however this can be calculated by using the information below.

air conditioning energy star rating

 

If the air conditioning unit has a heating and cooling function (reverse cycle) then a red sticker will be used for the heating star rating and a blue sticker for the cooling rating. Some newer appliances now have up to 10 stars to reflect there energy efficiency. If a product is rated at 6 stars or less, it will not show the extra star ‘super efficiency rating’ band above the normal six stars.air conditioning energy star rating

The above example shows that the unit is rated 7 stars while in the cooling mode and 4 stars in the heating mode. When comparing air conditioning units you can compare the effiency of different units using the star ratings. It is important that you compare these units with other units with the same or similar size. You can find the output size of the unit in the middle of the label as seen below.

 

Capacity output and power input

air conditioning energy star rating

These figures show you the amount of heating or cooling an air conditioning unit can produce. For air conditioners, the measure of energy efficiency is the Energy Efficiency Ratio (EER) for cooling and the Coefficient Of Performance (COP) for heating. The EER and COP are defined as the capacity output divided by the power input. This can be calculated in the above example as 4.75 (power output) divided by 0.82 (power input). This gives an EER of 5.79. The higher the EER and COP the more energy efficent the unit will be.

 

What Does Air Conditioning Energy Consumption Mean?

This is a number that represents how much electricity a particular model will use.

This is also based on standardised testing which is required by law and conducted in line with Australian and New Zealand standards.

This number can be used to let you know how much power this unit will consume over a year. You can use this number to compare any model – even if the sizes or capacities are not the same. A standard kilowatt is usually about .028 cents per hour – this can change depending on your electricity provider or change if you have solar panels.

air conditioning energy star rating consumption

The average cost to run a reverse cycle air conditioning unit is estimated to be between  $0.20 – $0.35 per hour. A medium sized room of 36sqm would cost $0.30 – $0.70 per hour to run. A larger area (50sqm) will cost between $0.70 and $1.00 per hour to run.

A ducted air conditioning unit can cost between $0.50 and $3.50 per hour to run. The amount of zones and rooms turned on at the same time can make a significant difference.

There are many factors to allow for when calculating a room. Window size and position, ceiling heights, direct sun onto walls, shading, insulation in the walls and roof and the amount of people or equipment in the room.

 

Air conditioning energy star rating calculator

air conditioning energy star rating calculator

 

An air conditioning energy star rating calculator can be viewed here  to rate air conditioning units and other appliances.

A free app can be downloaded on iTunes or Google Play

Once you have purchased your air conditioning unit make sure that it is well maintained and serviced. This will make sure that it is running at its peak and most efficient.

Having the indoor unit premium cleaned will make sure there is not a build up of mould and dirt in the coils, fan and in the drip tray.